PERFORMANCE
|
SPECIFICATIONS
|
PARAMETER
|
Insertion loss (multimode)
|
TIA/EIA-455-171
|
0.30dB – typical, 0.75dB – maximum
|
Insertion loss (single-mode)
|
TIA/EIA-455-171
|
0.40dB – typical, 0.75dB – maximum
|
Back reflection (single-mode UPC polish)
|
EIA/TIA-455-60
|
-50dB – typical, -40dB – maximum
|
Operating temperature
|
TIA/EIA-455-5
|
-54° C to + 85° C
|
Storage temperature
|
TIA/EIA-455-5
|
-65° C to + 85° C
|
Temperature cycling
|
TIA/EIA-455-3
|
-54° C to + 85° C
|
Mating durability
|
TIA/EIA-455-21
|
1000 cycles
|
Impact
|
TIA/EIA-455-2
|
Method B , omit wall pipe
|
Twist
|
TIA-455-36
|
±90° rotation, 1 cycle/5 sec., 1000 cycles
|
Cable sealing flex
|
MIL-STD-1344, method 2017
|
100 cycles
|
Cable retention
|
EIA/TIA-455-6
|
400 lbs. min.
|
Crush resistance
|
EIA-455-26
|
450 lbs.
|
Physical shock
|
EIA/TIA-455-14
|
Condition C
|
Vibration
|
MIL-STD-1344
|
Method 2005.1
|
Temperature humidity
|
TIA/EIA-455-5C
|
Method B
|
Fluid immersion
|
EIA/TIA-455-12
|
24 hours per fluid
|
Ozone exposure
|
ATSM-D-1149
|
100-150 PPM for 2 hours
|
Flammability
|
MIL-STD-1344
|
Method 1012
|
Corrosion resistance
|
EIA/TIA-455-16
|
500 hours salt spray
|
Thermal shock
|
TIA/EIA-455-71
|
Condition B-0 except 10 cycles @ 85℃ and -62℃
|