→Cable de Fibra Óptica Serie HC
- Designed for installation in an underground duct for data transmission between nodes or hubs
- Cable can also be routed vertically inside buildings
- Ideal for high-density network backbone installations
Features
- Rugged tight-buffered fiber unit construction
- Cable materials are Indoor/Outdoor: UV, fungus, and water resistant
- The high-density breakout cables offer a >20% reduction in diameter and a >20% reduction in weight relative to conventional loose-tube cables, allowing for greater fiber density and cable packing within a duct
- Meets all applicable standards for Impact & Crush Resistance (CSA C22.2 No. 230)
- UL listed in accordance with NEC 770.179(b) for use in vertical runs in building risers or from floor to floor
- Core-Locked™ outer jacket design for installation survivability
- Helically stranded core for greater flexibility and mechanical protection of the optical fibers
- Cable offers a cost savings by eliminating the need to splice outdoor cable at building entrance
- Cable can be terminated with 900µm fanout kit
- Construction options available for direct termination of tight-buffered fiber units to MPO/MTP connectors
- Suitable for direct pulling with wire mesh grips
- Oil resistance for use in industrial applications (J-Jacket)
- J-Jacket is UV, fungus, oil, and moisture resistant
Standars
OCC Indoor/Outdoor tight-buffered fiber optic cables meet the functional requirements of the following standards:
- UL 1666
- ICEA-S-104-696
- ICEA-S-83-596
- TIA-568
- TIA-598
Characteristics | PVC Outer Jacket | Low-Temperature PVC Outer Jacket |
---|---|---|
Operating Temp | -40°C to +85°C | -50°C to +75°C |
Storage Temp | -55°C to +85°C | -55°C to +80°C |
Install Temp | -10°C to +60°C | -20°C to +60°C |
Flame Retardancy | UL listed type OFNR (UL 1666) | UL listed type OFNR (UL 1666) |
Crush Resist | 1800 N/cm | 1,800 N/cm |
Flex Resist | 2000 cycles | 2,000 cycles |
Flex Resist | D | J |